Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
Add more filters










Publication year range
1.
Ann Biomed Eng ; 52(3): 657-670, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38079083

ABSTRACT

Interest in studying neonatal development and the improved healing response observed in neonates is increasing, with the goal of using this work to create better therapeutics for tendon injury. Decorin and biglycan are two small leucine-rich proteoglycans that play important roles in collagen fibrillogenesis to develop, maintain, and repair tendon structure. However, little is known about the roles of decorin and biglycan in early neonatal development and healing. The goal of this study was to determine the effects of decorin and biglycan knockdown on Achilles tendon structure and mechanics during neonatal development and recovery of these properties after injury of the neonatal tendon. We hypothesized that knockdown of decorin and biglycan would disrupt the neonatal tendon developmental process and produce tendons with impaired mechanical and structural properties. We found that knockdown of decorin and biglycan in an inducible, compound decorin/biglycan knockdown model, both during development and after injury, in neonatal mice produced tendons with reduced mechanical properties. Additionally, the collagen fibril microstructure resembled an immature tendon with a large population of small diameter fibrils and an absence of larger diameter fibrils. Overall, this study demonstrates the importance of decorin and biglycan in facilitating tendon growth and maturation during neonatal development.


Subject(s)
Achilles Tendon , Animals , Mice , Achilles Tendon/physiology , Biglycan/genetics , Collagen/chemistry , Decorin/genetics , Extracellular Matrix Proteins
2.
J Appl Physiol (1985) ; 136(1): 43-52, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37969085

ABSTRACT

Tendon injury and healing involve intricate changes to tissue metabolism, biology, and inflammation. Current techniques often require animal euthanasia or tissue destruction, limiting assessment of dynamic changes in tendon, including treatment response, disease development, rupture risk, and healing progression. Microdialysis, a minimally invasive technique, offers potential for longitudinal assessment, yet it has not been applied to rat tendon models. Therefore, the objective of this study is to adapt a novel application of an in vivo assay, microdialysis, using acute injury as a model for extreme disruption of the tendon homeostasis. We hypothesize that microdialysis will be able to detect measurable differences in the healing responses of acute injury with high specificity and sensitivity. Overall results suggest that microdialysis is a promising in vivo technique for longitudinal assessment for this system with strong correlations between extracellular fluid (ECF) and dialysate concentrations and reasonable recovery rates considering the limitations of this model. Strong positive correlations were found between dialysate and extracellular fluid (ECF) concentration for each target molecule of interest including metabolites, inflammatory mediators, and collagen synthesis and degradation byproducts. These results suggest that microdialysis is capable of detecting changes in tendon healing following acute tendon injury with high specificity and sensitivity. In summary, this is the first study to apply microdialysis to a rat tendon model and assess its efficacy as a direct measurement of tendon metabolism, biology, and inflammation.NEW & NOTEWORTHY This study adapts a novel application of microdialysis to rat tendon models, offering a minimally invasive avenue for longitudinal tendon assessment. Successfully detecting changes in tendon healing after acute injury, it showcases strong correlations between extracellular fluid and dialysate concentrations. The results highlight the potential of microdialysis as a direct measure of tendon metabolism, biology, and inflammation, bypassing the need for animal euthanasia and tissue destruction.


Subject(s)
Achilles Tendon , Tendon Injuries , Rats , Animals , Achilles Tendon/metabolism , Microdialysis , Tendon Injuries/metabolism , Rupture/metabolism , Rupture/surgery , Dialysis Solutions , Inflammation/metabolism
3.
J Biomech ; 145: 111393, 2022 12.
Article in English | MEDLINE | ID: mdl-36442431

ABSTRACT

Plantar flexor functional deficits measured using joint dynamometry are associated with poor outcomes in patients following Achilles tendon rupture. In this study, we developed a small animal dynamometer to quantify functional deficits in a rat Achilles tendon rupture model. Like our reported plantar flexor deficits in patients recovering from Achilles tendon ruptures, we found in our small animal model functional deficits across the ankle range of motion, resulting in an average 34% less positive work being done compared to the uninjured contralateral limb. These functional deficits are similar to 38% less plantar flexor work done by patients who were treated non-surgically in our prior research. Further, these torque deficits were greater in plantar flexion than dorsiflexion, which agree with clinical complaints of limited function during tasks like jumping and hiking. These findings serve as compelling evidence that our Sprague Dawley rat model of an Achilles tendon rupture recapitulates the functional deficits we observed in patients treated nonsurgically. We provide thorough documentation for other groups to build their own dynamometers, which can be modified to meet unique experimental criteria.


Subject(s)
Achilles Tendon , Animals , Rats , Rats, Sprague-Dawley , Achilles Tendon/injuries , Tears
4.
J Orthop Res ; 40(7): 1593-1603, 2022 07.
Article in English | MEDLINE | ID: mdl-34657312

ABSTRACT

Rotator cuff repair failure remains common due to poor tendon healing, particularly at the enthesis. We previously showed that pulsed electromagnetic field (PEMF) therapy improved the mechanical properties of the rat supraspinatus tendon postoperatively. However, little is known about the mechanisms behind PEMF-dependent contributions to improved healing in this injury model. The objective of this study was to determine the influence of PEMF treatment on tendon gene expression and cell composition, as well as bone microarchitecture and dynamic bone metabolism during early stages of healing. We hypothesized that PEMF treatment would amplify tendon-healing related signaling pathways while mitigating inflammation and improve bone metabolism at the repair site. Rats underwent rotator cuff injury and repair followed by assignment to either control (non-PEMF) or PEMF treatment groups. Gene and protein expression as well as tendon and bone histological assessments were performed 3, 7, 14, 21, and 28 days after injury. Gene expression data demonstrated an upregulation in the bone morphogenetic protein 2 signaling pathway and increases in pro-osteogenic genes at the insertion, supporting important processes to re-establish the tendon-bone interface. PEMF also downregulated genes related to a fibrotic healing response. Anti-inflammatory effects were demonstrated by both gene expression and macrophage phenotype. PEMF significantly increased the rate of kinetic bone formation directly adjacent to the tendon enthesis as well as the number of cuboidal surface osteoblasts (active osteoblasts) in the humeral head. This study has provided insight into how PEMF affects cellular and molecular processes in the supraspinatus tendon and adjacent bone after injury and repair.


Subject(s)
Rotator Cuff Injuries , Animals , Biomechanical Phenomena , Electromagnetic Fields , Rats , Rats, Sprague-Dawley , Rotator Cuff/pathology , Rotator Cuff Injuries/pathology , Wound Healing
5.
Am J Sports Med ; 50(1): 170-181, 2022 01.
Article in English | MEDLINE | ID: mdl-34851182

ABSTRACT

BACKGROUND: Achilles tendon ruptures are painful and debilitating injuries and are most common in middle-aged patients. There is a lack of understanding of the underlying causes for increased rupture rates in middle-aged patients and how healing outcomes after a rupture might be affected by patient age. Therefore, the objective of this study was to define age-specific Achilles tendon healing by assessing ankle functional outcomes and Achilles tendon mechanical and histological properties after a rupture using a rat model. HYPOTHESIS: Rats representing the middle-aged patient population would demonstrate reduced healing capability after an Achilles tendon rupture, as demonstrated by a slower return to baseline ankle functional properties and inferior biomechanical and histological tendon properties. STUDY DESIGN: Controlled laboratory study. METHODS: Fischer 344 rats were categorized by age to represent young, middle-aged, and old patients, and Achilles tendon ruptures were induced in the right hindlimb. Animals were allowed to heal and were euthanized at 3 or 6 weeks after the injury. In vivo functional assays and ultrasound imaging were performed throughout the healing period, and ex vivo tendon mechanical and histological properties were assessed after euthanasia. RESULTS: Rats representing middle-aged patients displayed reduced healing potential compared with the other age groups, as they demonstrated decreased recovery of in vivo functional and ultrasound assessment parameters and inferior mechanical and histological properties after an Achilles tendon rupture. CONCLUSION: These findings may help explain the increased rupture rate observed clinically in middle-aged patients by suggesting that there may be altered tendon responses to daily trauma. CLINICAL RELEVANCE: The results provide novel data on age-specific healing outcomes after an Achilles tendon rupture, which underscores the importance of considering a patient's age during treatment and expectations for outcomes.


Subject(s)
Achilles Tendon , Tendon Injuries , Achilles Tendon/diagnostic imaging , Animals , Humans , Rats , Rats, Inbred F344 , Rupture , Treatment Outcome , Wound Healing
6.
Ann Biomed Eng ; 49(2): 515-522, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33409852

ABSTRACT

The Achilles tendon, while the strongest and largest tendon in the body, is frequently injured. Even after surgical repair, patients risk re-rupture and long-term deficits in function. Poly-N-acetyl glucosamine (sNAG) polymer has been shown to increase the rate of healing of venous leg ulcers, and use of this material improved tendon-to-bone healing in a rat model of rotator cuff injury. Therefore, the purpose of this study was to investigate the healing properties of liquid sNAG polymer suspension in a rat partial Achilles tear model. We hypothesized that repeated sNAG injections throughout healing would improve Achilles tendon healing as measured by improved mechanical properties and cellular morphology compared to controls. Results demonstrate that sNAG has a positive effect on rat Achilles tendon healing at three weeks after a full thickness, partial width injury. sNAG treatment led to increased quasistatic tendon stiffness, and increased tangent and secant stiffness throughout fatigue cycling protocols. Increased dynamic modulus also suggests improved viscoelastic properties with sNAG treatment. No differences were identified in histological properties. Importantly, use of this material did not have any negative effects on any measured parameter. These results support further study of this material as a minimally invasive treatment modality for tendon healing.


Subject(s)
Acetylglucosamine/therapeutic use , Achilles Tendon/drug effects , Tendon Injuries/drug therapy , Achilles Tendon/injuries , Animals , Biomechanical Phenomena , Disease Models, Animal , Male , Rats, Sprague-Dawley , Tendon Injuries/physiopathology
7.
Ann Biomed Eng ; 49(5): 1333-1341, 2021 May.
Article in English | MEDLINE | ID: mdl-33145676

ABSTRACT

Cigarette smoking is the largest cause of preventable deaths, and a known risk factor for musculoskeletal issues including rotator cuff tendon tears. Tendon degeneration is believed to be due in part to changes in tendon cell health and collagen structure. Several studies have demonstrated that exposure to nicotine negatively impacts tendon healing, but surprisingly, nicotine exposure was shown to increase rat supraspinatus tendon stiffness. In order to address this seeming contradiction, the objective of this study was to comprehensively investigate the effects of long-term (18 weeks) exposure of nicotine on tendon-to-bone microstructural properties in a rat model. We hypothesized that long term subcutaneous nicotine delivery would lead to diminished tendon mechanical properties, decreased bone microstructure in the humeral head, and altered tendon cell morphology compared to age-matched control rats receiving saline. Results demonstrated a small decrease in tendon size and stiffness, with decreased cell density in the tendon midsubstance. However, no differences were found in the enthesis fibrocartilage or in the underlying subchondral or trabecular bone. In conclusion, our study revealed limited effects of nicotine on the homeostatic condition of the supraspinatus tendon, enthesis, and underlying bone. Future studies are needed to ascertain effects of other components of tobacco products.


Subject(s)
Humerus/drug effects , Nicotine/toxicity , Rotator Cuff/drug effects , Animals , Humerus/anatomy & histology , Humerus/diagnostic imaging , Humerus/physiology , Male , Rats, Sprague-Dawley , Rotator Cuff/anatomy & histology , Rotator Cuff/diagnostic imaging , X-Ray Microtomography
8.
Acta Biomater ; 111: 341-348, 2020 07 15.
Article in English | MEDLINE | ID: mdl-32428684

ABSTRACT

Many drug delivery systems rely on degradation or dissolution of the carrier material to regulate release. In cases where mechanical support is required during regeneration, this necessitates composite systems in which the mechanics of the implant are decoupled from the drug release profile. To address this need, we developed a system in which microspheres (MS) were sequestered in a defined location between two nanofibrous layers. This bilayer delivery system (BiLDS) enables simultaneous structural support and decoupled release profiles. To test this new system, PLGA (poly-lactide-co-glycolic acid) microspheres were prepared using a water-in-oil-in-water (w/o/w) emulsion technique and incorporated Alexa Fluor-tagged bovine serum albumin (BSA) and basic fibroblast growth factor (bFGF). These MS were secured in a defined pocket between two polycaprolactone (PCL) nanofibrous scaffolds, where the layered scaffolds provide a template for new tissue formation while enabling independent and local release from the co-delivered MS. Scanning electron microscopy (SEM) images showed that the assembled BiLDS could localize and retain MS in the central pocket that was surrounded by a continuous seal formed along the margin. Cell viability and proliferation assays showed enhanced cell activity when exposed to BiLDS containing Alexa Fluor-BSA/bFGF-loaded MS, both in vitro and in vivo. MS delivered via the BiLDS system persisted in a localized area after subcutaneous implantation for at least 4 weeks, and bFGF release increased colonization of the implant. These data establish the BiLDS technology as a sustained in vivo drug delivery platform that can localize protein and other growth factor release to a surgical site while providing a structural template for new tissue formation. STATEMENT OF SIGNIFICANCE: Localized and controlled delivery systems for the sustained release of drugs are essential. Many strategies have been developed for this purpose, but most rely on degradation (and loss of material properties) for delivery. Here, we developed a bilayer delivery system (BiLDS) that decouples the physical properties of a scaffold from its delivery kinetics. For this, biodegradable PLGA microspheres were sequestered within a central pocket of a slowly degrading nanofibrous bilayer. Using this device, we show enhanced cell activity with FGF delivery from the BiLDS both in vitro and in vivo. These data support that BiLDS can localize sustained protein and biofactor delivery to a surgical site while also serving as a mechanical scaffold for tissue repair and regeneration.


Subject(s)
Drug Delivery Systems , Lactic Acid , Drug Liberation , Microspheres , Polylactic Acid-Polyglycolic Acid Copolymer
9.
J Orthop Res ; 38(11): 2339-2349, 2020 11.
Article in English | MEDLINE | ID: mdl-32215953

ABSTRACT

The high prevalence of tendon retear following rotator cuff repair motivates the development of new therapeutics to promote improved tendon healing. Controlled delivery of non-steroidal anti-inflammatory drugs to the repair site via an implanted scaffold is a promising option for modulating inflammation in the healing environment. Furthermore, biodegradable nanofibrous delivery systems offer an optimized architecture and surface area for cellular attachment, proliferation, and infiltration while releasing soluble factors to promote tendon regeneration. To this end, we developed a bilayer delivery system (BiLDS) for localized and controlled release of ibuprofen (IBP) to temporally mitigate inflammation and enhance tendon remodeling following surgical repair by promoting organized tissue formation. In vitro evaluation confirmed the delayed and sustained release of IBP from Labrafil-modified poly(lactic-co-glycolic) acid microspheres within sintered poly(ε-caprolactone) electrospun scaffolds. Biocompatibility of the BiLDS was demonstrated with primary Achilles tendon cells in vitro. Implantation of the IBP-releasing BiLDS at the repair site in a rat rotator cuff injury and repair model led to decreased expression of proinflammatory cytokine, tumor necrotic factor-α, and increased anti-inflammatory cytokine, transforming growth factor-ß1. The BiLDS remained intact for mechanical reinforcement and recovered the tendon structural properties by 8 weeks. These results suggest the therapeutic potential of a novel biocompatible nanofibrous BiLDS for localized and tailored delivery of IBP to mitigate tendon inflammation and improve repair outcomes. Future studies are required to define the mechanical implications of an optimized BiLDS in a rat model beyond 8 weeks or in a larger animal model.


Subject(s)
Anti-Inflammatory Agents, Non-Steroidal/administration & dosage , Drug Delivery Systems , Ibuprofen/administration & dosage , Rotator Cuff Injuries/drug therapy , Animals , Cells, Cultured , Disease Models, Animal , Drug Evaluation, Preclinical , Male , Microspheres , Rats , Rats, Sprague-Dawley
10.
J Orthop Res ; 38(1): 70-81, 2020 01.
Article in English | MEDLINE | ID: mdl-31595543

ABSTRACT

The Achilles tendon is frequently injured. Data to support specific treatment strategies for complete and partial tears is inconclusive. Regardless of treatment, patients risk re-rupture and typically have long-term functional deficits. We previously showed that pulsed electromagnetic field (PEMF) therapy improved tendon-to-bone healing in a rat rotator cuff model. This study investigated the effects of PEMF on rat ankle function and Achilles tendon properties after (i) complete Achilles tendon tear and repair with immobilization, (ii) partial Achilles tendon tear without repair and with immobilization, and (iii) partial Achilles tendon tear without repair and without immobilization. We hypothesized that PEMF would improve tendon properties, increase collagen organization, and improve joint function, regardless of injury type. After surgical injury, animals were assigned to a treatment group: (i) no treatment control, (ii) 1 h of PEMF per day, or (iii) 3 h of PEMF per day. Animals were euthanized at 1, 3, and 6 weeks post-injury. Joint mechanics and gait analysis were assessed over time, and fatigue testing and histology were performed at each time point. Results indicate no clear differences in Achilles healing with PEMF treatment. Some decreases in tendon mechanical properties and ankle function suggest PEMF may be detrimental after complete tear. Some early improvements were seen with PEMF after partial tear with immobilization; however, immobilization was found to be a confounding factor. This body of work emphasizes the distinct effects of PEMF on tendon-to-bone healing and supports trialing potential treatment strategies pre-clinically across tendons before applying them clinically. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 38:70-81, 2020.


Subject(s)
Magnetic Field Therapy , Tendon Injuries/therapy , Achilles Tendon/injuries , Animals , Male , Rats, Sprague-Dawley
11.
J Biomech ; 88: 194-200, 2019 May 09.
Article in English | MEDLINE | ID: mdl-30952452

ABSTRACT

The Achilles tendon, while the strongest and largest tendon in the body, is frequently injured. Inconclusive evidence exists regarding treatment strategies for both complete tears and partial tears. Well-characterized animal models of tendon injury are important for understanding physiological processes of tendon repair and testing potential therapeutics. Utilizing three distinct models of rat Achilles tendon injury, the objective of this study was to define and compare the effects and relative impact on tendon properties and ankle function of both tear severity (complete tear versus partial tear, both with post-operative immobilization) and immobilization after partial tear (partial tear with versus without immobilization). We hypothesized that a complete tear would cause inferior post-injury properties compared to a partial tear, and that immediate loading after partial tear would improve post-injury properties compared to immobilization. All models were reproducible and had distinct effects on measured parameters. Injury severity drastically influenced tendon healing, with complete tear causing decreased ankle mobility and tendon mechanics compared to partial tears. One week of plantarflexion immobilization had a strong effect on animals receiving a partial tear. Tendons with partial tears and immobilization failed early during fatigue cycling three weeks post-injury. Partial tear without immobilization had no effect on ankle range of motion through dorsiflexion at any time point compared to the pre-surgery value, while partial tear with immobilization demonstrated diminished function at all post-injury time points. All three models of Achilles injury could be useful for tendon healing investigations, chosen based on the prospective applications of a potential therapeutic.


Subject(s)
Achilles Tendon/injuries , Achilles Tendon/physiopathology , Ankle/physiopathology , Tendon Injuries/physiopathology , Animals , Male , Postoperative Period , Range of Motion, Articular , Rats, Sprague-Dawley , Plastic Surgery Procedures , Rupture/surgery , Tendon Injuries/surgery
13.
J Orthop Res ; 37(1): 94-103, 2019 01.
Article in English | MEDLINE | ID: mdl-30345583

ABSTRACT

Nicotine is harmful to many bodily systems; however, the effects of nicotine on intra-substance tendon healing remain largely unexplored. The purpose of this study was to examine the functional, structural, and biomechanical effects of nicotine on the healing of Achilles tendons in rats after an acute full-thickness injury. Sixty Sprague-Dawley rats were enrolled in this study. Half were exposed to 0.9% saline and half to 61 ng/mL of nicotine for 3 months via subcutaneous osmotic pumps. At 3 months, all rats underwent blunt full thickness transection of the left Achilles tendon and were immobilized for one week in plantarflexion. In-vivo assays were conducted prior to injury, at 21 days, and at 42 days post-injury and included the following: Functional limb assessment, passive joint mechanics, and vascular evaluation. Rats were sacrificed at 21 and 42 days for biomechanical testing and histologic evaluation. Rats exposed to nicotine demonstrated decreased vascularity, greater alteration in gait mechanics, and increased passive ROM of the ankle joint. Biomechanically, the nicotine tendons failed at lower maximum loads, were less stiff, had smaller cross-sectional areas and had altered viscoelastic properties. Histologically, nicotine tendons demonstrated decreased vessel density at the injury site. This study demonstrates that nicotine leads to worse functional outcomes and biomechanical properties in tendons. The decreased vascularity in the nicotine group may suggest an underlying mechanism for inferior tendon healing. Patients should be counseled that using nicotine products increase their risk of poor tendon healing and may predispose them to tendon re-rupture. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.


Subject(s)
Achilles Tendon/drug effects , Ganglionic Stimulants/adverse effects , Nicotine/adverse effects , Regeneration/drug effects , Tendon Injuries , Achilles Tendon/injuries , Achilles Tendon/pathology , Animals , Male , Rats, Sprague-Dawley
14.
Am J Sports Med ; 46(14): 3486-3494, 2018 12.
Article in English | MEDLINE | ID: mdl-30419172

ABSTRACT

BACKGROUND: Lesions of the long head of the biceps tendon are often associated with massive rotator cuff tears (MRCTs), and biceps tenotomy is frequently performed for pain relief and functional reservation. However, the efficacy and safety of biceps tenotomy regarding the effects on the surrounding tissues in chronic MRCT are unclear. HYPOTHESIS: Biceps tenotomy would result in improved mechanical and histological properties of the intact subscapularis tendon and improved in vivo shoulder function while not compromising glenoid cartilage properties. STUDY DESIGN: Controlled laboratory study. METHODS: Right supraspinatus and infraspinatus tendons were detached in 25 male Sprague-Dawley rats, followed by 4 weeks of cage activity to create a chronic MRCT condition. Animals were randomly divided into 2 groups and received either biceps tenotomy (n = 11) or sham surgery (n = 14) and were sacrificed 4 weeks thereafter. Forelimb gait and ground-reaction forces were recorded 1 day before the tendon detachment (baseline), 1 day before the surgical intervention (biceps tenotomy or sham), and 3, 7, 10, 14, 21, and 28 days after the intervention to assess in vivo shoulder joint function. The subscapularis tendon and glenoid cartilage were randomly allocated for mechanical testing or histologic assessment after the sacrifice. RESULTS: Compared with sham surgery, biceps tenotomy partially restored the in vivo shoulder joint function, with several gait and ground-reaction force parameters returning closer to preinjury baseline values at 4 weeks. With biceps tenotomy, mechanical properties of the subscapularis tendons were improved, while mechanical properties and histological Mankin scores of the glenoid cartilage were not diminished when compared with the sham group. CONCLUSION: Biceps tenotomy in the presence of chronic MRCT partially preserves overall shoulder function and potentially restores subscapularis tendon health without causing detrimental effects to joint cartilage. This laboratory study adds to the growing literature regarding the protective effects of biceps tenotomy on the shoulder joint in a chronic MRCT model. CLINICAL RELEVANCE: This study provides important basic science evidence supporting the use of biceps tenotomy in patients with massive rotator cuff tears.


Subject(s)
Hamstring Tendons/surgery , Rotator Cuff Injuries/physiopathology , Rotator Cuff Injuries/surgery , Shoulder Joint/physiology , Tenotomy , Animals , Cartilage, Articular/physiology , Disease Models, Animal , Forelimb/physiology , Gait Analysis , Male , Random Allocation , Rats , Rats, Sprague-Dawley , Scapula/physiopathology
15.
J Shoulder Elbow Surg ; 27(3): 553-560, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29174271

ABSTRACT

BACKGROUND: Rotator cuff tears affect millions of individuals each year, often requiring surgical intervention. However, repair failure remains common. We have previously shown that pulsed electromagnetic field (PEMF) therapy improved tendon-to-bone healing in a rat rotator cuff model. The purpose of this study was to determine the influence of both PEMF frequency and exposure time on rotator cuff healing. METHODS: Two hundred ten Sprague-Dawley rats underwent acute bilateral supraspinatus injury and repair followed by either Physio-Stim PEMF or high-frequency PEMF therapy for 1, 3, or 6 hours daily. Control animals did not receive PEMF therapy. Mechanical and histologic properties were assessed at 4, 8, and 16 weeks. RESULTS: Improvements in different mechanical properties at various endpoints were identified for all treatment modalities when compared with untreated animals, regardless of PEMF frequency or duration. Of note, 1 hour of Physio-Stim treatment showed significant improvements in tendon mechanical properties across all time points, including increases in both modulus and stiffness as early as 4 weeks. Collagen organization improved for several of the treatment groups compared with controls. In addition, improvements in type I collagen and fibronectin expression were identified with PEMF treatment. An important finding was that no adverse effects were identified in any mechanical or histologic property. CONCLUSIONS: Overall, our results suggest that PEMF therapy has a positive effect on rat rotator cuff healing for each electromagnetic fundamental pulse frequency and treatment duration tested in this study.


Subject(s)
Magnetic Field Therapy/methods , Rotator Cuff Injuries/therapy , Wound Healing , Animals , Disease Models, Animal , Male , Rats , Rats, Sprague-Dawley , Plastic Surgery Procedures , Rotator Cuff/surgery , Tendons/surgery
16.
J Am Acad Orthop Surg ; 25(9): 635-647, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28837456

ABSTRACT

INTRODUCTION: Achilles tendon ruptures affect 15 of 100,000 women and 55 of 100,000 men each year. Controversy continues to exist regarding optimal treatment and rehabilitation protocols. The objective of this study was to investigate the temporal effects of surgical repair and immobilization or activity on Achilles tendon healing and limb function after complete transection in rodents. METHODS: Injured tendons were repaired (n = 64) or left nonrepaired (n = 64). The animals in both cohorts were further randomized into groups immobilized in plantar flexion for 1, 3, or 6 weeks that later resumed cage and treadmill activity for 5, 3, or 0 weeks, respectively (n = 36 for each regimen), which were euthanized at 6 weeks after injury, or into groups immobilized for 1 week and then euthanized (n = 20). RESULTS: At 6 weeks after injury, the groups that had 1 week of immobilization and 5 weeks of activity had increased range of motion and decreased ankle joint toe stiffness compared with the groups that had 3 weeks of immobilization and 3 weeks of activity. The groups with 6 weeks of immobilization and no activity period had decreased tendon cross-sectional area but increased tendon echogenicity and collagen alignment. Surgical treatment dramatically decreased fatigue cycles to failure in repaired tendons from groups with 1 week of immobilization and 5 weeks of activity. Normalized comparisons between 1-week and 6-week postinjury data demonstrated that changes in tendon healing properties (area, alignment, and echogenicity) were maximized by 1 week of immobilization and 5 weeks of activity, compared with 6 weeks of immobilization and no activity period. DISCUSSION: This study builds on an earlier study of Achilles tendon fatigue mechanics and functional outcomes during early healing by examining the temporal effects of different immobilization and/or activity regimens after initial postinjury immobilization. CONCLUSION: This study demonstrates how the temporal postinjury healing response of rodent Achilles tendons depends on both surgical treatment and the timing of immobilization/activity timing. The different pattern of healing and qualities of repaired and nonrepaired tendons suggest that two very different healing processes may occur, depending on the chosen immobilization/activity regimen.


Subject(s)
Achilles Tendon/injuries , Immobilization/methods , Wound Healing/physiology , Achilles Tendon/surgery , Animals , Male , Random Allocation , Range of Motion, Articular , Rats , Rats, Sprague-Dawley , Time Factors
17.
J Biomech ; 56: 55-60, 2017 05 03.
Article in English | MEDLINE | ID: mdl-28366437

ABSTRACT

Conservative treatment (non-operative) of Achilles tendon ruptures is suggested to produce equivalent capacity for return to function; however, long term results and the role of return to activity (RTA) for this treatment paradigm remain unclear. Therefore, the objective of this study was to evaluate the long term response of conservatively treated Achilles tendons in rodents with varied RTA. Sprague Dawley rats (n=32) received unilateral blunt transection of the Achilles tendon followed by randomization into groups that returned to activity after 1-week (RTA1) or 3-weeks (RTA3) of limb casting in plantarflexion, before being euthanized at 16-weeks post-injury. Uninjured age-matched control animals were used as a control group (n=10). Limb function, passive joint mechanics, tendon properties (mechanical, histological), and muscle properties (histological, immunohistochemical) were evaluated. Results showed that although hindlimb ground reaction forces and range of motion returned to baseline levels by 16-weeks post-injury regardless of RTA, ankle joint stiffness remained altered. RTA1 and RTA3 groups both exhibited no differences in fatigue properties; however, the secant modulus, hysteresis, and laxity were inferior compared to uninjured age-matched control tendons. Despite these changes, tendons 16-weeks post-injury achieved secant stiffness levels of uninjured tendons. RTA1 and RTA3 groups had no differences in histological properties, but had higher cell numbers compared to control tendons. No changes in gastrocnemius fiber size or type in the superficial or deep regions were detected, except for type 2x fiber fraction. Together, this work highlights RTA-dependent deficits in limb function and tissue-level properties in long-term Achilles tendon and muscle healing.


Subject(s)
Achilles Tendon/physiology , Tendon Injuries/physiopathology , Animals , Ankle Joint/physiology , Biomechanical Phenomena , Male , Muscle, Skeletal/physiology , Range of Motion, Articular , Rats, Sprague-Dawley , Wound Healing
18.
J Orthop Res ; 35(4): 902-909, 2017 04.
Article in English | MEDLINE | ID: mdl-27282093

ABSTRACT

Rotator cuff tears are common musculoskeletal injuries often requiring surgical intervention with high failure rates. Currently, pulsed electromagnetic fields (PEMFs) are used for treatment of long-bone fracture and lumbar and cervical spine fusion surgery. Clinical studies examining the effects of PEMF on soft tissue healing show promising results. Therefore, we investigated the role of PEMF on rotator cuff healing using a rat rotator cuff repair model. We hypothesized that PEMF exposure following rotator cuff repair would improve tendon mechanical properties, tissue morphology, and alter in vivo joint function. Seventy adult male Sprague-Dawley rats were assigned to three groups: bilateral repair with PEMF (n = 30), bilateral repair followed by cage activity (n = 30), and uninjured control with cage activity (n = 10). Rats in the surgical groups were sacrificed at 4, 8, and 16 weeks. Control group was sacrificed at 8 weeks. Passive joint mechanics and gait analysis were assessed over time. Biomechanical analysis and µCT was performed on left shoulders; histological analysis on right shoulders. Results indicate no differences in passive joint mechanics and ambulation. At 4 weeks the PEMF group had decreased cross-sectional area and increased modulus and maximum stress. At 8 weeks the PEMF group had increased modulus and more rounded cells in the midsubstance. At 16 weeks the PEMF group had improved bone quality. Therefore, results indicate that PEMF improves early tendon healing and does not alter joint function in a rat rotator cuff repair model. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:902-909, 2017.


Subject(s)
Bone and Bones/pathology , Electromagnetic Fields , Rotator Cuff Injuries/therapy , Rotator Cuff/pathology , Tendons/pathology , Animals , Biomechanical Phenomena , Cross-Sectional Studies , Joints/pathology , Male , Rats , Rats, Sprague-Dawley , Stress, Mechanical , Tendon Injuries/physiopathology , Wound Healing , X-Ray Microtomography
19.
J Orthop Res ; 35(6): 1250-1257, 2017 06.
Article in English | MEDLINE | ID: mdl-27500782

ABSTRACT

Rotator cuff tendon tears are one of the most common shoulder pathologies, especially in the aging population. Due to a poor healing response and degenerative changes associated with aging, rotator cuff repair failure remains common. Although cell-based therapies to augment rotator cuff repair appear promising, it is unknown whether the success of such a therapy is age-dependent. We hypothesized that autologous cell therapy would improve tendon-to-bone healing across age groups, with autologous juvenile cells realizing the greatest benefit. In this study, juvenile, adult, and aged rats underwent bilateral supraspinatus tendon repair with augmentation of one shoulder with autologous tendon-derived cell-seeded polycaprolactone scaffolds. At 8 weeks, shoulders treated with cells in both juvenile and aged animals exhibited increased cellularity, increased collagen organization, and improved mechanical properties. No changes between treated and control limbs were seen in adult rats. These findings suggest that cell delivery during supraspinatus repair initiates earlier matrix remodeling in juvenile and aged animals. This may be due to the relative "equilibrium" of adult tendon tissue with regards to catabolic and anabolic processes, contrasted with actively growing juvenile tendons and degenerative aged tendons. This study demonstrates the potential for autologous cell-seeded scaffolds to improve repairs in both the juvenile and aged population. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1250-1257, 2017.


Subject(s)
Aging/physiology , Cell- and Tissue-Based Therapy/methods , Rotator Cuff Injuries/therapy , Rotator Cuff/physiology , Tissue Scaffolds , Animals , Collagen/metabolism , Male , Primary Cell Culture , Rats, Inbred F344 , Tendons/cytology , Tendons/physiology , Transplantation, Autologous
SELECTION OF CITATIONS
SEARCH DETAIL
...